Crestron Allen and Heath SQ
Intro PriceThis module controls an Allen & Heath SQ-5, SQ-6 or SQ-7 digital mixer from a Crestron program over the mixer’s network port: MIDI over TCP, port 51325, as Allen & Heath’s SQ MIDI Protocol (Issue 5, firmware V1.5.0 or later) describes it. Every mixer parameter is an NRPN; the module computes the parameter numbers, sends the mixer’s own messages and applies every value the mixer sends. It is a SIMPL+ module: it is compiled into your SIMPL Windows program and exposes ordinary digital, analog and serial signals.
Screenshots
Overview
Crestron program over the mixer’s network port: MIDI over TCP, port 51325, as Allen & Heath’s SQ MIDI Protocol (Issue 5, firmware V1.5.0 or later) describes it.
Every mixer parameter is an NRPN; the module computes the parameter numbers, sends the mixer’s own messages and applies every value the mixer sends.
It is a SIMPL+ module: it is compiled into your SIMPL Windows program and exposes ordinary digital, analog and serial signals.
Features
Controls an Allen & Heath SQ-5, SQ-6 or SQ-7 digital mixer from a Crestron 3-Series or 4-Series program over the mixer's network port (MIDI over TCP, port 51325; no login is documented and none is asked for): faders, pans, mutes, mix masters, DCAs, mute groups, sends, scenes and soft keys, with feedback for the faders, pans, mutes, masters, DCAs, mute groups and sends.
Control
- Input channels 1-48: fader (to LR), pan, mute on / off / toggle, level up / down with a held repeat.
- Mix masters: LR, Aux 1-12, FX Send 1-4, Matrix 1-3 - level, mute.
- DCA 1-8: level, mute. Mute groups 1-8.
- Sends: every input's level and assignment to one selected Aux or FX send (
Send_Mix_Select). - Scene recall 1-300. Soft Keys 1-16, press and release (a key does what it is assigned to on the mixer).
- Raw MIDI as hex: one message of up to 127 bytes, sent as typed, for what is not on a signal (group masters and routing, FX return routing, the sends' pans, MIDI strips, MMC, soft rotaries). Input gain, EQ and dynamics are not in the SQ MIDI protocol at all.
- Levels and pans as analog 0-65535 = the mixer's own 14-bit value x 4 (60784 = 0 dB on the Linear Taper law; pan centre 32764).
Feedback
- The module's own sets are shown at once; every value the mixer sends is applied to the control it
belongs to.
Refreshre-reads everything. - A full read-back at connect and on
Refresh(the firstInput_Countinputs, every mix master, DCA, mute group and the selected send's rows); the level is read back after every burst of up / down steps. - The last changed input and mix level as text (
-20.0 dB), in the mixer's Linear or Audio Taper law (every row of the vendor's Audio Taper table). Scene_Fbis the last scene this module recalled (the mixer reports none); Soft Keys have no feedback.
Connection
- Local network only; a persistent TCP connection that reconnects by itself after a drop or a failed attempt (every 5 seconds).
- A heartbeat read of LR every
Poll_Seconds(2-600):Responding_Fbsays whether the mixer answers. A fader ramp never silences it. - Commands leave in batches of up to eight frames per 50 ms: 48 frames in 0.3 s, 96 in 0.6 s. A full
command queue or ring is reported on
Last_Error$. - Diagnostics on the module's own signals: connection status, last command, last value, last error, and traffic counters.
Licensing
- 30-minute trial on every program start; no code needed to evaluate.
- Activation with an offline activation code from the AchKayEm licensing portal (product
allen-and-heath-sq-crestron). The processor needs no internet connection. - The license is stored on the processor and checked again on every start. Several of these modules on one processor share one activation.
- An offline activation code is tied to a processor's MAC address. The tie is checked only when a Console symbol
is wired to give the module the processor's MAC; without it the code is accepted on any processor and the module
says
processor not checked. The binding is advisory in this form.
Requirements. An Allen & Heath SQ-5, SQ-6 or SQ-7 on firmware V1.5.0 or later, reachable on TCP port 51325; its MIDI channel and NRPN Fader Law set in the module's parameters. A Crestron 3-Series or 4-Series control system programmed in SIMPL Windows.
Version history
- Initial Release