✨ New🚀 Early AccessCrestron SIMPL+ module for NovaStar VX Series LED video controllers (VX400, VX600, VX1000 and the VX Pro family): brightness, display mode, test patterns, presets, layer sources and input status over TCP.
🚀 Early Access: an untested release. It may have bugs or missing features and will change before 1.0. Sales are final. Your license includes 1.0 and every later update.
Screenshots
Overview
Control brightness as a percentage or on the controller's own 0-255 scale, display mode (normal, freeze, fade to black), test patterns, presets 1-10, and the sources of layers 1 to 3. On a VX400, VX600 or VX1000 the module also switches between primary and backup. A raw command input reaches anything else, and refuses a factory reset.
Every poll reads back the signal, resolution and frame rate of each input, the controller's Mode ID and, on a VX Pro, its primary/backup mode. A refused command is named on the module's error output, with a hint when the Model setting is the likely cause.
The download includes the SIMPL+ module (.usp and .ush), a sample SIMPL Windows program, an HTML5 touch panel, a join reference and the manual. Built for 3-Series and 4-Series processors, over the local network; RS-232 and USB control are not supported. A 30-minute trial runs on every program start, and activation uses an offline code, so the processor needs no internet connection.
Features
A SIMPL+ module for NovaStar VX Series all-in-one LED video controllers: brightness, display mode,
test patterns, presets and layer sources, with the state of the controller's inputs read back. One
module for both families, chosen by its Model parameter: the VX400 / VX600 / VX1000 (TCP port 5200)
and the VX Pro family - VX400 Pro, VX600 Pro, VX1000 Pro, VX2000 Pro (TCP port 15200). One module per
controller. The controllers have no power command and no input routing.
Untested on any NovaStar controller. The module is built from AchKayEm's copy of NovaStar's protocol documents and tested against emulators of both families written from the same copy. The only report from the field is of AchKayEm's Q-SYS plugin sending the VX1000 commands to a VX1000 Pro: brightness worked and nothing else did. No VX Pro command, and no command to a VX400 / VX600 / VX1000, has yet been seen to work (see the change log).
Control
- Brightness as a percentage or on the controller's own 0-255 scale, and a pulse that sends the level again
- Display mode: normal, freeze, fade to black
- Test patterns: each family's own set, chosen by number and applied by a pulse
- Presets 1-10: recall from ten buttons or by number; save by a deliberate select-then-save step
- The source of layers 1 to 3, from the inputs the selected model has
- Primary / backup switching on a VX400 / VX600 / VX1000
- A raw command input for other commands of up to 127 bytes, checked for form (not for what it does) before it is sent; a factory reset is refused
- Commands go out in the order they were made; a level changed several times goes once with its newest value, but never across a button pressed in between. Nothing is sent to the wall when the program starts or the module reconnects
Feedback
- Read from the controller at every poll: signal, resolution and frame rate of eight inputs, with the model's input names; the Mode ID; on a VX Pro, the primary / backup mode
- Brightness, display mode, test pattern, last preset and layer sources: the last value this module sent and the controller acknowledged - no read of them is documented, so a change made from the controller's front panel or other software is not seen
- A refused command is named, with a hint when the
Modelparameter is the likely cause
Connection
- Local network only.
- One TCP connection, kept open and polled; designed to reconnect by itself 5 seconds after it drops, and to report a controller that stops answering after about 20 seconds (not yet measured on a processor).
- Diagnostics on the module's own signals: connection status, last command, last response, last error, and traffic counters.
Licensing
- 30-minute trial on every program start; no code needed to evaluate.
- Activation with an offline activation code from the AchKayEm licensing portal. The processor needs no internet connection. A stored license always takes precedence over a newly entered code.
- A code names the processor it is for; the module checks that only when the program gives it the processor's MAC address, so the tie to a processor is advisory.
- The license is meant to be stored on the processor and checked again on every start; storage on a processor is still to be confirmed.
Requirements. A NovaStar VX400, VX600, VX1000, VX400 Pro, VX600 Pro, VX1000 Pro or VX2000 Pro with a fixed address, reachable from the processor over TCP (port 5200 or 15200). A Crestron control system programmed in SIMPL Windows; the module is built for 3-Series and 4-Series (compiled for both, not yet run on either). RS-232 and USB control are not supported in this release.