Crestron Avarro V2 Displays Driver
✨ New🚀 Early AccessCrestron SIMPL+ module for Avarro Pro E Series displays (V2-P43ES, V2-P50ES, V2-P55ES, V2-P65ES): power, source, volume, picture settings and status over the display's LAN control port.
🚀 Early Access: an untested release. It may have bugs or missing features and will change before 1.0. Sales are final. Your license includes 1.0 and every later update.
Screenshots
Overview
Power on and off (Active Standby), toggle and restart; source select for HDMI 1 and 2, HDMI 3 and 4 where the display has them, and OPS; volume level, steps and mute; backlight, brightness, contrast, sharpness, picture mode, colour temperature, zoom, video blank and panel lock. Remote keys and a raw command input reach the rest of Avarro's command table.
Feedback covers power, source, volume, mute and every picture setting, plus the model, serial number, software version, signage ID, IP address, running time and CPU temperature. Changes made at the display or by another controller are picked up by the next poll, and the module warns when the display's Power Mode is Eco, in which it cannot be woken over the network. The line ending is selectable, and a late reply is never credited to the wrong command.
The download includes the SIMPL+ module (.usp and .ush), a sample SIMPL Windows program, an HTML5 touch panel, a join reference and the manual. Built for 3-Series and 4-Series processors. The display needs Power Mode set to Standard and a fixed address. A 30-minute trial runs on every program start, and activation uses an offline code, so the processor needs no internet connection.
Features
Controls Avarro Pro E Series displays over the local network, using the display's LAN control port (TCP 1986), with a SIMPL+ module that exposes ordinary digital, analog and serial signals. Written from the vendor's V2-P55ES manual, whose cover names the V2-P43ES, V2-P50ES, V2-P55ES and V2-P65ES; not yet tested with any of them.
Control
- Power on, power off (Active Standby - the display has no other off), power toggle, restart.
- Source: HDMI 1 and HDMI 2; HDMI 3 and HDMI 4 on a display that has them (the vendor gives most models two HDMI inputs); OPS with an OPS module installed. DisplayPort and Type-C are in the vendor's command table, but no Avarro document shows them on these models.
- Volume level (0-100), step up and down, mute toggle / on / off.
- Backlight, brightness, contrast, sharpness (0-100); picture mode 1-5; colour temperature; picture zoom; video blank; panel lock.
- Remote keys and a raw command passthrough for the rest of the vendor's command table. Of the eleven key buttons, only Up and Menu are names the vendor's manual shows; the others are unconfirmed.
Feedback
- Power, source (as a button state, an index and the panel's own text), volume, mute, picture settings, picture mode, colour temperature, zoom, video, panel lock.
- Model, serial number, software version, signage ID, IP address, display running time (in minutes, as the panel reports it), CPU temperature.
- A warning when the panel's Power Mode is Eco (it cannot then be woken over the network).
- Changes made at the panel or by another controller are picked up by the next poll.
Connection
- Local network only. Reconnects by itself after a network interruption.
- Selectable command line ending (CR, LF or CRLF). The vendor does not say which a display wants; if it does not answer, try CRLF first.
- After a request goes unanswered, and on every new connection, the module re-synchronises before it believes another answer: a late answer is never credited to another request, however late and on whichever connection it arrives, provided the display answers in order, once per request, and sends nothing unasked (it is counted and dropped). Three exceptions: when all four of the module's status questions are themselves still owed (four or more unanswered requests in a row across a reconnect), when more answers are owed than the module can list (about ten), and answers owed from before the program started. Replies that do not fit the waiting command, and a display that repeats each command back, are recognised and ignored.
- Diagnostics on the module's own signals: connection status, last command, last response, last error, and traffic counters (including late and echoed lines).
Licensing
- 30-minute trial on every program start; no code needed to evaluate.
- Activation with an offline activation code from the AchKayEm licensing portal. The processor needs no internet connection.
- The license is stored on the processor and checked again on every start (that it survives a reboot, and a change of program, is still to be confirmed on a processor).
Requirements. An Avarro Pro E Series display on the network with Power Mode = Standard (Display Settings > Signage Settings > Power Up Settings) and a fixed address; a Crestron control system programmed in SIMPL Windows. The module is built for 3-Series and 4-Series: compiled for both; version 0.4.8 ran on a 4-Series processor (an RMC4) against an emulator of the display; not yet run on a 3-Series. Not yet tested against a real display.
Version history
Beta Pre-release